FIELD OF USE : Testing the Location, distribution, direction, and diameter of the rebar and the thickness of concrete cover
in concrete structure projects such as bridges, tunnels, walls etc. Detecting Ferro magnets in non-ferromagnetic media.
ZBL-R660 Intergrated Rebar Detector is
- Bridge, tunnel, wall and other concrete structures in the location of steel, steel distribution and direction, the thinkness of the protective layer, the detection of steel bar diameter
- also for non-ferromagnetic media in the ferromagnetic and electrical conductivity (such as wires, pipelines) to the detection and distribution of detection
- Inspection and acceptance of construction quality of concrete structures
- Evaluate the safety and durability of the building under construction
- The old structure to assess the transformation of the amount of reinforcement detection
- The floor or wall of the cable, plumbling pipes and other distribution and direction to detect.
QUALITY STEMS FROM THE PROFESSIONAL
- Professional R&D team
- Production department
- After layers of quality inspection
- Users at ease choice
FEATURES
- Integrated design
– Host and sensor synthesis, on-site operation is convenient and fast - All information with the screen display
– Reinforcement location, spacing, protective layer thickness useful information at a glance - Three- dimensinal imaging
– Can clearly reproduce the distribution of the internal distribution of steel bars - Multi-coil structure
– Faster, more accurate - Semi-semi-reflective color LCD screen
– Whether in outdoor light or indoor dark show information are clearly visible - Support round steel, rebar mode
– Test results are more accurate - Wireless data transmission
– Seamless ZBL engineering Test Management System
- EVALUATE THE SAFETY AND DURABILITY
- DETECTING FERRO MAGNETS
- INTEGRATED DESIGN
- ACCURATE TEST RESULTS
- WIRELESS DATA TRANSMISSION
- THREE YEARS HOST WARRANTY
SPECIFICATION
Protective layer thickness range (mm) | ɸ6~ ɸ50 | |
Max. range | First Range | 1~80 |
Secnd Range | 1~180 | |
Max. allowed error | ±1 (mm) | 1~59 |
±2 (mm) | 50~78 | |
±4 (mm) | 70~180 | |
Applicable range (mm) | ɸ6~ ɸ32 | |
Max. allowed error for diameters measurement | ±1 | |
Common type | ü | |
Closely bars type | ü | |
Transverse section bars | ü | |
Grid type | ü | |
Signal wave | Real time display | |
Scan range | Borderless | |
Data correction | Automatic | |
Data transfer | Wi-Fi/USB | |
Wireless transfer | ü | |
LCD | 320 x 240 | |
Power | Built-in battery | |
Size (mm) | 240 x 93 x 110 | |
Weight (kg) | 0.67 |